×
Register Here to Apply for Jobs or Post Jobs. X

Fire Sprinkler & Fire Alarm Inspector

Job in Auburn, Lee County, Alabama, 36831, USA
Listing for: Atlantis-Fire-Protection
Full Time position
Listed on 2026-10-12
Job specializations:
  • Trades / Skilled Labor
    Security Systems Installation, Field/Service Technician, Maintenance Technician / Mechanic
Salary/Wage Range or Industry Benchmark: 48000 - 62000 USD Yearly USD 48000.00 62000.00 YEAR
Job Description & How to Apply Below
POSITION SUMMARY

I ndependently performs scheduled inspection, testing, and documentation of water-based fire protection, fire alarm, and backflow prevention systems. Identifies deficiencies, communicates life-safety impacts, maintains required credentials, and delivers complete, accurate, and timely reports in accordance with adopted codes, manufacturer instructions, company procedures, and jurisdictional requirements.

ESSENTIAL DUTIES &

ACCOUNTABILITIES
  • Plan assigned routes, confirm site contacts and access, review prior reports and system history, arrive within scheduled windows, and maintain professional communication with customers and office staff.
  • Inspect and test wet, dry, preaction, deluge, standpipe, fire pump, private fire service main, hydrant, water-storage, and related water-based systems in accordance with NFPA 25 and the adopted edition required by the authority having jurisdiction.
  • Inspect and functionally test fire alarm control units, initiating devices, notification appliances, supervising stations, power supplies, interfaces, releasing functions, and sprinkler supervisory/alarm signals in accordance with NFPA 72 and approved procedures.
  • Perform backflow prevention assembly testing using properly maintained and calibrated test equipment; complete utility/AHJ forms and comply with UF TREEO certification and local water-purveyor requirements.
  • Conduct main-drain, waterflow, valve, alarm, supervisory, battery, sensitivity, fire-pump, trip, and other required tests without creating avoidable impairment, property damage, false dispatch, or disruption to customer operations.
  • Coordinate monitoring-system test status, impairment notifications, fire-watch needs, shutdowns, restorations, and acceptance of systems with customers, supervising stations, service teams, and authorities as required.
  • Document device counts, locations, readings, results, deficiencies, photos, model/serial information, test-equipment data, and corrective recommendations in company software; issue required tags and reports accurately and on time.
  • Classify deficiencies consistently, explain findings without overstating code authority, identify urgent life-safety conditions, and generate clear repair recommendations and service leads for estimating and follow-up.
  • Perform limited troubleshooting and minor corrections only within training, authorization, licensing, and approved scope; obtain approval before billable repairs and elevate design, programming, or impairment issues.
  • Maintain custody, calibration status, and readiness of meters, gauges, backflow kits, smoke/heat test equipment, ladders, tools, labels, and vehicle stock; report damaged or out-of-tolerance equipment immediately.
  • Follow OSHA, company, customer, electrical-safety, ladder/lift, PPE, lockout/tagout, confined-space, and impairment procedures; report incidents, near misses, unsafe conditions, and accidental activations immediately.
  • Maintain required licenses, permits, certifications, continuing education, manufacturer training, and code knowledge; support after-hours, weekend, emergency, and regional assignments when business needs require.
REQUIRED QUALIFICATIONS & CREDENTIALS
  • High school diploma or GED and at least two years of relevant inspection/service experience. Strong working knowledge of NFPA 25, NFPA 72, inspection frequencies, test procedures, impairments, and deficiency documentation.
  • Current NICET Level II certification in Inspection and Testing of Water-Based Systems and NICET Level II in Inspection and Testing of Fire Alarm Systems required. A candidate holding one may be considered if qualified to obtain the second within a company-approved period.
  • Current UF TREEO Backflow Prevention Assembly Tester certification, including required two-year recertification;
    Backflow Repair and Maintenance certification preferred. Must also hold any water-purveyor approvals required for assigned territories.
  • For Florida assignments: active Water-Based Fire Protection Inspector Permit and Fire Alarm System Agent (FASA) credential required as applicable; BASA required only when assigned burglar/security system work. Maintain all state/local permits and continuing education.
  • Proficient with inspection software, mobile devices, digital reports, email, photos, and basic electrical/mechanical test equipment; able to read plans, riser diagrams, sequence-of-operations documents, and inspection records.
  • Valid driver's license with an acceptable driving record; authorized to work in the United…
To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)
0
200
Filters
Education Level
Experience Level (years)
Posted in last:
Salary