Fire Sprinkler & Fire Alarm Inspector
Job in
Auburn, Lee County, Alabama, 36831, USA
Listed on 2026-10-12
Listing for:
Atlantis-Fire-Protection
Full Time
position Listed on 2026-10-12
Job specializations:
-
Trades / Skilled Labor
Security Systems Installation, Field/Service Technician, Maintenance Technician / Mechanic
Job Description & How to Apply Below
I ndependently performs scheduled inspection, testing, and documentation of water-based fire protection, fire alarm, and backflow prevention systems. Identifies deficiencies, communicates life-safety impacts, maintains required credentials, and delivers complete, accurate, and timely reports in accordance with adopted codes, manufacturer instructions, company procedures, and jurisdictional requirements.
ESSENTIAL DUTIES &ACCOUNTABILITIES
- Plan assigned routes, confirm site contacts and access, review prior reports and system history, arrive within scheduled windows, and maintain professional communication with customers and office staff.
- Inspect and test wet, dry, preaction, deluge, standpipe, fire pump, private fire service main, hydrant, water-storage, and related water-based systems in accordance with NFPA 25 and the adopted edition required by the authority having jurisdiction.
- Inspect and functionally test fire alarm control units, initiating devices, notification appliances, supervising stations, power supplies, interfaces, releasing functions, and sprinkler supervisory/alarm signals in accordance with NFPA 72 and approved procedures.
- Perform backflow prevention assembly testing using properly maintained and calibrated test equipment; complete utility/AHJ forms and comply with UF TREEO certification and local water-purveyor requirements.
- Conduct main-drain, waterflow, valve, alarm, supervisory, battery, sensitivity, fire-pump, trip, and other required tests without creating avoidable impairment, property damage, false dispatch, or disruption to customer operations.
- Coordinate monitoring-system test status, impairment notifications, fire-watch needs, shutdowns, restorations, and acceptance of systems with customers, supervising stations, service teams, and authorities as required.
- Document device counts, locations, readings, results, deficiencies, photos, model/serial information, test-equipment data, and corrective recommendations in company software; issue required tags and reports accurately and on time.
- Classify deficiencies consistently, explain findings without overstating code authority, identify urgent life-safety conditions, and generate clear repair recommendations and service leads for estimating and follow-up.
- Perform limited troubleshooting and minor corrections only within training, authorization, licensing, and approved scope; obtain approval before billable repairs and elevate design, programming, or impairment issues.
- Maintain custody, calibration status, and readiness of meters, gauges, backflow kits, smoke/heat test equipment, ladders, tools, labels, and vehicle stock; report damaged or out-of-tolerance equipment immediately.
- Follow OSHA, company, customer, electrical-safety, ladder/lift, PPE, lockout/tagout, confined-space, and impairment procedures; report incidents, near misses, unsafe conditions, and accidental activations immediately.
- Maintain required licenses, permits, certifications, continuing education, manufacturer training, and code knowledge; support after-hours, weekend, emergency, and regional assignments when business needs require.
- High school diploma or GED and at least two years of relevant inspection/service experience. Strong working knowledge of NFPA 25, NFPA 72, inspection frequencies, test procedures, impairments, and deficiency documentation.
- Current NICET Level II certification in Inspection and Testing of Water-Based Systems and NICET Level II in Inspection and Testing of Fire Alarm Systems required. A candidate holding one may be considered if qualified to obtain the second within a company-approved period.
- Current UF TREEO Backflow Prevention Assembly Tester certification, including required two-year recertification;
Backflow Repair and Maintenance certification preferred. Must also hold any water-purveyor approvals required for assigned territories. - For Florida assignments: active Water-Based Fire Protection Inspector Permit and Fire Alarm System Agent (FASA) credential required as applicable; BASA required only when assigned burglar/security system work. Maintain all state/local permits and continuing education.
- Proficient with inspection software, mobile devices, digital reports, email, photos, and basic electrical/mechanical test equipment; able to read plans, riser diagrams, sequence-of-operations documents, and inspection records.
- Valid driver's license with an acceptable driving record; authorized to work in the United…
To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
Search for further Jobs Here:
×