Water Quality Sampling Technician – Sterile Processing Services; SPS
-
Healthcare
-
Science
Job Description & How to Apply Below
Company: I-2-I Solutions
Location: Boston, West Roxbury, and Brockton, Massachusetts
Work Environment: On-site at three VA Medical Centers
Schedule: Monday–Friday, 7:30 AM–4:00 PM, on scheduled sampling days
Anticipated Project Start: March 2027, subject to contract award and final scheduling
I-2-I Solutions is seeking an experienced Water Quality Sampling Technician to support water quality testing services at three Department of Veterans Affairs (VA) medical facilities in Massachusetts.
The selected candidate will be responsible for collecting water samples, performing applicable on-site water quality measurements, preparing samples for laboratory testing, and maintaining accurate sampling documentation in accordance with ANSI/AAMI ST108:2023 – Water for the Processing of Medical Devices and project requirements.
The position supports the water systems serving the hospitals' Sterile Processing Services (SPS), including critical water, utility water, and steam systems.
The work involves recurring monthly and quarterly sampling, as well as additional sampling when water quality results fall outside established limits.
Primary Responsibilities Water Sampling and Field TestingPerform scheduled water sampling at three VA Medical Centers in accordance with the approved sampling plan and project requirements.
Collect samples from all designated sampling points, including individual fixtures within the Sterile Processing Service areas.
Sample reverse osmosis (RO) water systems, including points of generation, return loops, and designated critical-water sinks.
Collect samples from washer-disinfectors, Medivator units, and associated decontamination sinks.
Collect utility-water samples from designated generation points, sinks, ultrasonic equipment, and other specified fixtures.
Collect samples from designated steam system testing points.
Perform applicable on-site chemistry measurements, including pH, conductivity, total alkalinity, and total hardness, using calibrated instruments and approved procedures.
Collect samples for laboratory analysis of Heterotrophic Plate Count (HPC) and bacterial endotoxin.
Follow applicable ANSI/AAMI ST108:2023 sampling procedures and the specific testing requirements for critical water, utility water, and steam.
Collect samples separately from each required fixture rather than using a single representative sample for multiple fixtures.
Use appropriate sampling containers, labeling, collection techniques, and quality control procedures.
Maintain accurate records of sampling locations, collection dates and times, field readings, and other required sampling information.
Properly label, package, preserve, and prepare collected water samples for laboratory analysis.
Maintain sample traceability and chain-of-custody documentation.
Follow applicable sample temperature, preservation, transportation, and holding-time requirements.
Coordinate timely delivery or shipment of collected samples to the designated laboratory.
Ensure time-sensitive samples, particularly microbiological samples, are handled and delivered in accordance with applicable testing requirements.
Coordinate with the laboratory and project management team regarding sample submissions and any collection issues.
Perform quarterly sampling at designated utility-water and steam testing points.
Be available for unscheduled resampling following out-of-range water quality results.
Complete required resampling within two business days
, during normal business hours.Report unusual field readings, sampling difficulties, or potential water quality concerns promptly to the project…
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
View / Apply for Jobs
Matching My Jurisdiction