×
Register Here to Apply for Jobs or Post Jobs. X

Reliability Engineer – Electrical & Power Systems; HV to LV

Job in Fort Worth, Tarrant County, Texas, 76102, USA
Listing for: Iris Energy
Full Time position
Listed on 2026-10-24
Job specializations:
  • Engineering
    Electrical Engineering
Salary/Wage Range or Industry Benchmark: 120000 - 190000 USD Yearly USD 120000.00 190000.00 YEAR
Job Description & How to Apply Below

Job Type: Full Time |
Location: Dallas/Fort Worth |
Department: Engineering |
Reporting to: Senior Manager, Asset Management & Governance |
Work Location Type
: #hybrid#remote

IRENis a vertically integrated AI Cloud provider, delivering large-scale datacenters and GPU clusters for AI training and inference. IREN's platform is underpinned by its expansive portfolio of grid-connected land and power in renewable-rich regions across North America, Europe and APAC.

The Reliability Engineer - Electrical Systems will be the pillar's technical authority for the reliability of IREN's data center electrical infrastructure from utility and high-voltage intake through medium- and low-voltage distribution to the critical load - substations, transformers, switch gear, generators, ATS/STS, UPS, PDU/RPP and busway, protection and controls. The role develops and maintains the enterprise electrical maintenance and testing strategies, ensures every maintenance plan meets IEEE, NFPA, NETA and applicable standards, owns the electrical switching, testing and procedure standards the sites execute, and leads root-cause investigations into electrical failures.

It is a hands-on support role to the site teams: reviewing and witnessing switching and testing, supporting incidents, approving fit-for-purpose deviations proposed by campus Asset Managers, and mentoring site engineers and technicians.

With 100% renewable energy, we build, own and operate our data centers and take pride in being at the forefront of sustainable solutions for the ever-evolving applications of high-performance compute. We believe that human progress is invaluable, but it should be done in the right way - responsibly, sustainably and having a positive impact on the communities we operate in.

Job requirements

  • Bachelor's degree in Electrical Engineering or a related discipline;
    Professional Engineer (PE) licensure, CMRP, CRE or NETA/ETT Level III-IV certification is an asset.
  • 7+ years in electrical reliability, maintenance engineering or critical-facilities electrical operations, with demonstrable data center experience across HV, MV and LV systems.
  • Deep working knowledge of data center electrical architecture and procedures: utility intake and substations, MV/LV switch gear, transformers, generators and paralleling, ATS/STS, UPS and battery systems, PDU/RPP/busway, protection, grounding and EPMS; N+1 / 2N topologies, maintenance bypass and concurrent maintainability.
  • Experience developing and executing switching orders, MOPs/EOPs and energized/de-energized work controls; competent in LOTO and electrical safety under NFPA 70E and OSHA 29 CFR 1910 Subpart S.
  • Experience with electrical acceptance and maintenance testing to ANSI/NETA ATS and MTS: insulation resistance, power factor/tan delta, transformer DGA and TTR, breaker primary/secondary injection and trip testing, protection-relay coordination, VLF cable testing, battery impedance and capacity testing, infrared thermography and ultrasound.
  • Proven root-cause analysis capability using structured methods (5-Whys, Ishikawa/fishbone, fault tree analysis, event and causal factor charting, Apollo or TapRooT, Kepner-Tregoe, FMEA/FMECA) with the discipline to distinguish failure symptom, mode, mechanism and root cause.
  • Working command of the governing standards: NFPA 70 (NEC), NFPA 70B (Electrical Equipment Maintenance), NFPA 70E, NFPA 110/111; IEEE 3007.2, IEEE 493 (Gold Book), IEEE 1584 (arc flash), IEEE C37 and C57 series, IEEE 450/1188/1106 (batteries); ANSI/NETA ATS, MTS and ETT;
    Uptime Institute Tier and TIA-942 practices; ISO 55001.
  • Familiarity with reliability analytics — MTBF/MTTR, Weibull, Pareto and bad-actor analysis, P-F interval and condition-based strategy design — and with CMMS data (e.g., Fiix, Maximo, SAP PM) and EPMS/power-quality systems.
  • Clear, measured communicator able to work with technicians, site engineers, OEMs, NETA firms and executives; willing to travel to campuses and support incidents outside normal hours when required
Other important requirements
  • Pre-employment screening, including background check and substance testing may be required according to company policies.
  • Must provide own steel-toed work boots; other PPE will be supplied.
  • Must be able to reliably commute to the work site daily or have plans to relocate before starting work.
  • Regular travel to the Childress campus and other IREN sites is required; availability to support electrical incidents outside normal hours as needed.
Job responsibilities
  • Electrical…
To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)
0
200
Filters
Education Level
Experience Level (years)
Posted in last:
Salary