More jobs:
Shift Lead - Data Center Operations
Job in
600016, Meenambakkam, Tamil Nadu, India
Listed on 2026-08-29
Listing for:
Larsen & Toubro-Vyoma
Full Time
position Listed on 2026-08-29
Job specializations:
-
Maintenance/Cleaning
Maintenance Technician / Mechanic
Job Description & How to Apply Below
1. Job Purpose
Lead safe, reliable and SLA-compliant operation of the 30 MW data center during the assigned shift. The role is accountable for real-time monitoring, maintenance coordination, incident command, change control, customer support and shift-team performance across electrical, mechanical, fire-life-safety, security and automation systems. The Shift Lead acts as the single operational owner on duty and ensures disciplined execution of SOPs, MOPs and EOPs, accurate escalation, and complete shift handover.
2. Role Scope and Critical Infrastructure
Electrical: utility/GIS interface, transformers, MV/LT switch gear, bus ducts, DG systems, UPS, batteries, STS/ATS, PDUs/RPPs, earthing and lightning protection.
Mechanical: chillers, cooling towers or heat-rejection systems, pumps, PAHU/AHU/CRAH units, chilled-water network, valves, VFDs, ventilation, plumbing and water-treatment systems.
High-density cooling, where deployed: CDUs, primary and technology-cooling loops, liquid-cooling alarms, leak detection, pressure, flow and temperature monitoring.
Fire and life safety: FAS, VESDA, clean-agent/fire-suppression systems, hydrant/sprinkler systems, emergency exits and emergency response equipment.
Monitoring and security: BMS, EPMS, DCIM, WLD, CCTV, access control, public-address and related command-center systems.
Customer environments: white-space power and cooling availability, rack power provisioning, remote-hands coordination and approved customer activity support.
3. Key Accountabilities
A. Shift Command and 24x7 Monitoring
Assume formal charge of the facility at shift start, review open risks, alarms, impairments, ongoing work, capacity constraints and customer commitments.
Maintain continuous command-center oversight of BMS, EPMS, DCIM, FAS, VESDA, WLD, CCTV and access-control alarms; ensure each alarm is acknowledged, validated, recorded and closed or escalated.
Deploy shift engineers and technicians based on risk, permit status, workload and competency; maintain minimum required coverage across critical areas.
Conduct scheduled facility rounds and verify equipment health, operating parameters, redundancy status, housekeeping, safety conditions and abnormal indications.
Maintain a clear operating picture of available capacity, redundancy, equipment under maintenance, bypass conditions and temporarily impaired protection.
B. Incident, Emergency and Escalation Management
Act as first incident commander for alarms, equipment trips, utility disturbances, cooling excursions, leaks, fire alarms, security events and customer-impacting conditions.
Execute the approved EOP, stabilize the facility, protect people and assets, preserve redundancy, and escalate through the defined communication matrix.
Open and manage incident tickets, maintain a timestamped event log, coordinate technical response, provide factual updates and drive restoration within agreed SLA/TAT.
Ensure preservation of evidence, event logs, trends and witness inputs; support preliminary incident reports and detailed RCA/corrective-action closure.
Initiate emergency services, OEM or management support in accordance with site procedures and authority limits.
C. Maintenance and Change Control
Plan and control preventive, predictive, condition-based and breakdown maintenance during the shift without compromising safety, redundancy or customer service.
Verify approved work order, risk assessment, method statement, permit-to-work, isolation/LOTO, rollback plan, test instruments, spares and competent manpower before work begins.
Lead pre-work briefing and post-work validation; confirm system normalization, alarm clearance, removal of temporary arrangements and closure of permits and change records.
Coordinate OEMs and vendors, verify attendance and workmanship, track observations, and escalate overdue maintenance, defects and repeat failures.
Raise and manage change requests for site work, configuration updates, maintenance and commissioning; stop work when controls are inadequate or conditions deviate from approval.
D. Capacity, Efficiency and Customer Delivery
Monitor electrical and cooling loading, operating margins and redundancy; escalate threshold breaches and emerging capacity risks.
Track shift-level energy and water performance indicators, including PUE/WUE inputs, abnormal consumption and avoidable simultaneous or unloaded operation.
Coordinate approved power provisioning, energization, commissioning, capacity augmentation and customer delivery activities.
Manage customer calls, service requests, incident communications and remote-hands support within approved scope and access controls.
Protect customer confidentiality and ensure activities in white space are executed with authorization, escort, ESD controls and accurate closure records.
E. Safety, Compliance and Audit Readiness
Enforce electrical, mechanical, work-at-height, hot-work, confined-space, lifting and chemical-safety controls applicable to activities during the shift.
Ensure permits, LOTO, PPE, toolbox talks,…
Note that applications are not being accepted from your jurisdiction for this job currently via this jobsite. Candidate preferences are the decision of the Employer or Recruiting Agent, and are controlled by them alone.
To Search, View & Apply for jobs on this site that accept applications from your location or country, tap here to make a Search:
To Search, View & Apply for jobs on this site that accept applications from your location or country, tap here to make a Search:
Search for further Jobs Here:
×