×
Register Here to Apply for Jobs or Post Jobs. X

Substation Design Engineer

Job in Lewisville, Denton County, Texas, 75029, USA
Listing for: Primoris Services Corporation
Full Time position
Listed on 2025-11-19
Job specializations:
  • Engineering
    Electrical Engineering, Systems Engineer
Salary/Wage Range or Industry Benchmark: 80000 - 100000 USD Yearly USD 80000.00 100000.00 YEAR
Job Description & How to Apply Below

Join to apply for the Engineer I Design role at Primoris Services Corporation

Will be located in Lewisville on a Hybrid Schedule

Duties & Responsibilities
  • Create design documents and drawings:
    Work within a project team to develop all project deliverables, including wiring diagrams from schematics, bills of materials, and applying field mark‑ups to as‑built drawings with minimal supervision.
  • Perform engineering support tasks:
    Conduct calculations such as relay burden, lighting, load flow, and short circuit with minimal supervision.
  • Apply engineering software:
    Use tools for tasks like ground grid design, relay coordination, transformer sizing, load flow, and short circuit studies with minimal supervision.
  • Review schedules:
    Monitor project timelines and collaborate with project engineers to keep projects on track.
  • Apply standards:
    Adhere to NEC, NESC, NEMA, IEEE, and ANSI standards.
  • Use document management:
    Properly utilize systems for project documentation.
  • Apply corporate practices:
    Follow Primoris standard engineering procedures.
  • Communicate and coordinate:
    Coordinate with project engineers, customer representatives, and others.
  • Gain hands‑on experience:
    Spend time at job sites for training in substation construction and design.
  • Ensure quality:
    Take ownership of work accuracy and quality.
  • Identify issues:
    Report potential problems and solutions to supervisors.
  • Travel:
    Occasional short‑term out‑of‑town travel for projects.
  • Other duties:
    As assigned by management.
Minimum Qualifications & Experience Education
  • Bachelor’s degree in Electrical Engineering (or equivalent) from an accredited university.
Required Experience
  • Senior applicants must be a licensed Professional Engineer (PE) with ability to obtain licensure in multiple states or gain it within one year of hire.
Technical Skills & Knowledge
  • Relays and Metering:
    Familiarity with electrical relays in the electric power utility industry; experience applying relays and metering in substations at 138kV and above.
  • P&C Design

    Experience:

    Designing electrical schematics for relay applications and control systems; designing connection drawings and cabling.
  • Physical Design

    Experience:

    Performing physical design for stations of varying voltage classes. Apply industry standards to produce and a safe and functional substation while value engineering for efficient and cost‑effective construction.
  • Studies:
    Interpret and apply the results of studies including grounding, lighting, lightning, short circuit, reactive power, TOV, harmonics and relay coordination. Ability to perform these studies is a plus.
  • Fundamentals:
    Strong knowledge of AC/DC principles; three‑phase power systems; per‑unit mathematics and symmetrical components.
  • Substation Knowledge:
    Understanding of substation components and functions; design documents and drawings needed for projects.
  • Standards:
    Knowledge of NEC, NESC, NEMA, IEEE, and ANSI.
  • Software:
    Proficiency in common word processing, spreadsheets, and email tools.
Soft Skills
  • Effective communication with co‑workers, vendors, and clients.
  • Ability to work in a team environment.

EEO Statement:
We are an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, national origin, disability status, protected veteran status, or any other characteristic protected by law.

Third Party Agency Notice:
Primoris will not accept any unsolicited resumes from any third‑party recruiting agencies either domestic or international. Primoris nor its subsidiaries will be responsible for any fees from the use of any unsolicited resumes either through our ATS or via electronic mail systems from any agency representative or agency consultant unless your firm is an approved vendor partner with a current executed agreement.

Referrals increase your chances of interviewing at Primoris Services Corporation by 2x

Apply BELOW

To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)

Job Posting Language
Employment Category
Education (minimum level)
Filters
Education Level
Experience Level (years)
Posted in last:
Salary