×
Register Here to Apply for Jobs or Post Jobs. X

Design Lead; Secondary; Substation; Electrical

Job in Sharjah, UAE/Dubai
Listing for: L&T Hydrocarbon Engineering
Full Time position
Listed on 2026-10-11
Job specializations:
  • Engineering
    Electrical Engineering, Systems Engineer, Engineering Design & Technologists
Salary/Wage Range or Industry Benchmark: 300000 - 550000 AED Yearly AED 300000.00 550000.00 YEAR
Job Description & How to Apply Below
Position: Design Lead (Secondary) - Substation (Electrical)

As a Design Lead Secondary the person shall be capable of defining reviewing amp executing Secondary Engineering Activities for Substation Power Distribution Projects He must have advanced knowledge in Protection amp Automation System in Substation The person shall be thorough with protection applications She He shall coordinate with vendors for finalization of the equipment She He shall lead a team of Engineers and Draughtspersons for timely completion of the Engineering activities within budget He shall maintain quality of engineering deliverables

Key Responsibilities Timely Delivery of Engineering Drawings amp Documents

Ensure deliveries are aligned to Project Schedule Provide and obtain spatial requirements and details of cut-outs and openings to Design Lead Primary Review primary drawings by Design Engineers amp Draughtspersons amp checking of design amp sizing calculations of primary engineering electrical equipment and obtaining approvals from the client

Prepare Design Philosophy of Protection Control Signalling amp Automation and review of Functional Description document

Review of Vendor deliverables pertaining to Secondary Engineering Define the philosophies on protection control signalling amp interfacing for lead Capable of Multitasking and deliver multiple things on time Estimate and Plan man-hour requirement

Reviewing of BOQ and submission to contracts team and providing technical clarifications

Coordinating with Operations team and informing Design specifications for obtaining approval

Coordinate with multiple disciplines for ensuring inter-departmental checks

Provide support amp clarifications to the Site Execution team Check pre-award evaluation of vendors w r t technical specifications requirement of the client and forwarding the validation document to Supply Chain Management Inspect equipment from the finalized vendor after submission of validation document of the vendor

Technical expertise

The Design Lead Secondary is required to have an overall knowledge of System Studies Control amp Protection requirement preparation of Schedules Layouts and associated calculations She He is also required to have hands on experience of design Software The Design Lead Secondary is required to have knowledge on National and International Codes and Standards She he should have the understanding of Secondary Engineering activities like Schemes Wiring Diagrams SCADA amp Control System He she shall have knowledge in CT VT sizing calculations battery sizing calculations AC DC schematic drawings The Secondary Design Lead should also have detailed knowledge of Substation equipment and their Layouts The Design Lead Primary is required to understand and interpret the contractual technical requirements and facilitate the Project Teams as and when required The person is required have an overall understanding of interface knowledge with Telecom systems applicable for Substation

Software Skills Required

General Awareness of MS Office Desirable knowledge of ETAP PSCAD CYMEGRID The Design Lead (Secondary) is required to have an overall knowledge of System Studies, Control & Protection requirement, preparation of Schedules, Layouts and associated calculations. She / He is also required to have hands on experience of design Software. The Design Lead (Secondary) is required to have knowledge on National and International Codes and Standards She / he should have the understanding of Secondary Engineering activities like Schemes, Wiring Diagrams, SCADA & Control System.

He / she shall have knowledge in CT / VT sizing calculations, battery sizing calculations, AC/DC schematic drawings. The Secondary Design Lead should also have detailed knowledge of Substation equipment and their Layouts. The Design Lead (Primary) is required to understand and interpret the contractual technical requirements and facilitate the Project Teams as and when required. The person is required have an overall understanding of interface knowledge with Telecom systems applicable for Substation.

General Awareness of MS Office Desirable knowledge of ETAP, PSCAD, CYMEGRID

To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)
0
200
Filters
Education Level
Experience Level (years)
Posted in last:
Salary