×
Register Here to Apply for Jobs or Post Jobs. X

Staffing - Facilities Engineer III

Job in Charlotte, Mecklenburg County, North Carolina, 28202, USA
Listing for: Mindlance
Full Time position
Listed on 2026-09-01
Job specializations:
  • Engineering
    Electrical Engineering
Job Description & How to Apply Below

Multi Cloud Administrator

Reporting to the Operations lead of Global Compute platforms, the Multi Cloud Administrator is a technology leader that will be responsible for end-to-end facilities for on-site computer rooms at manufacturing locations, with a primary focus on: IT electrical load planning (kW/rack, amperage, phases, A/B feeds, redundancy paths) UPS and battery backup strategy (runtime targets, capacity management, maintenance/test plans) Rack elevations and layout design (power/thermal/weight validation, growth planning, cable paths) Overall computer room design (power distribution, environmental requirements, physical/security controls, and facilities readiness).

Power Requirements & Electrical Design (IT Load Planning)

  • Own IT power demand planning for manufacturing computer rooms: establish current and future rack power budgets, peak load assumptions, and growth buffers.
  • Produce/maintain documentation of power source paths, redundancy assumptions, and room feeding approach (e.g., dual feeds, generator transfer) consistent with site DR and readiness documentation practices
  • Coordinate with plant electrical/facilities teams on electrical capacity, panel space, circuits, breakers, and phased expansions.

UPS / Battery Backup Engineering & Runtime Targets

  • Define UPS strategy (central room UPS vs. rack UPS) and ensure capacity supports business uptime needs.
  • Manage UPS lifecycle: sizing, runtime targets, monitoring, inspection cadence, testing, vendor maintenance coordination, and replacement planning.
  • Support sites where UPS utilization is already a risk: e.g., communications on maintaining a "stop-gap" utilization threshold and planning larger capacity upgrades.
  • Perform troubleshooting and improvement planning for UPS/battery systems aligned with critical facilities operating practices.

Rack Elevations, Physical Layout, and Capacity Modeling

  • Create and maintain rack elevations and "as-built" room layouts to support safe installation, maintenance access, and growth.
  • Ensure racks are designed and positioned to support safe servicing, cable length constraints, and practical workflows as part of overall computer room layout best practices.
  • Maintain CAD-style documentation and keep drawings current as the environment evolves.

Site Readiness, Modernization Support, and Constraint Removal

  • Partner with IT infrastructure modernization programs (e.g., dual-room resiliency to identify and eliminate physical constraints like insufficient UPS power, rack space limits, and lack of dual connections.
  • Drive remediation plans in coordination with facilities teams while minimizing production impact.

Operational Excellence:
Risk, Change, and Incident Support

  • Serve as the facilities escalation point for computer room power events, and participate in root cause analysis and remediation planning for electrical failures.
  • [] Establish/maintain SOPs/MOPs for planned power work, UPS maintenance, rack adds/moves/changes, and room upgrades.
  • Provide QA/QC oversight for contractor work impacting computer rooms and critical electrical paths.

Stakeholder, Vendor, and Contractor Management

  • Manage vendor relationships for UPS, battery, and monitoring systems; coordinate quotes, SOWs, and delivery timelines for upgrades (including cases where site power capacity expansion is required).
  • Collaborate with plant maintenance on generator/transfer readiness and testing practices where applicable.
  • Provide overall management of the Struxureware DCIM Platform.

Education Requirements Bachelor's degree (B.A.) or equivalent from four-year college in computer science or related field or equivalent experience

Work Experience 5+ years of experience in critical facilities / electrical infrastructure / data center or computer room environments, ideally supporting industrial or manufacturing facilities Hands-on expertise with UPS systems, battery technologies, and electrical distribution, including troubleshooting and operational safety protocols. Demonstrated capability producing and maintaining rack elevations/layouts and validating power/thermal/weight constraints. Experience with generators, ATS/STS units, and mission-critical electrical systems operations.

Familiarity with industry data center tiering concepts and reliability-oriented design thinking

Required Skills Travel Up to 10%, domestic and international EEO: "Mindlance is an Equal Opportunity Employer and does not discriminate in employment on the basis of – Minority/Gender/Disability/Religion/LGBTQI/Age/Veterans."

To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)
0
200
Filters
Education Level
Experience Level (years)
Posted in last:
Salary