×
Register Here to Apply for Jobs or Post Jobs. X

Control Room Supervisor

Job in Killona, Louisiana, 70066, USA
Listing for: Entergy
Full Time position
Listed on 2026-02-15
Job specializations:
  • Engineering
    Electrical Engineering
Salary/Wage Range or Industry Benchmark: 60000 - 80000 USD Yearly USD 60000.00 80000.00 YEAR
Job Description & How to Apply Below
Location: Killona

Job Title: Control Room Supervisor

Work Place Flexibility: Onsite

Legal Entity: Entergy Operations, Inc.

-EOI

This posting will fill 4 vacancies.
* Relocation assistance is provided.
* ** Selected candidates will move into the Control Room Supervisor position upon successful completion of the initial licensing class and SRO examination as detailed below.**

Job Summary /Purpose

The Control Room Supervisor ensures the safe and efficient operation of the plant, such that the health and safety of the workers and public are not jeopardized; give safety and quality a clear priority over schedule and cost; supervise the activities of the control room staff through all conditions of startup, shutdown power generation, and emergency.

Job Duties /Responsibilities
  • Monitor and supervise plant operations in the Control Room.
  • Coordinate with support staff to ensure that operations outside the Control Room are performed in a safe and controlled manner.
  • Authorize and manage Control room access.
  • Assure compliance with all applicable regulations and procedures.
  • Authorize, in conjunction with the Shift Manager and support staff, the implementation of scheduled or unscheduled work activities affecting station equipment, including corrective and preventative maintenance, modifications and protective tagging.
  • Utilize the station's corrective action programs to address issues and opportunities for improvement.
  • Actively participate in training and personnel development opportunities.
  • Participate in pre‑ and post‑job evolutions.
  • Assesses component operability/reportability.
  • Communicate technical information, concepts, and ideas verbally and in writing.
  • Serve as a member of the Emergency Response Organization.
Duties/Responsibilities And Requirements – Initial License Training (ILT) Class
  • Complete training program to obtain NRC SRO License
  • Self‑regulated study time and field time, as necessary, to maintain ILT performance within standards
  • Complete ILT Fundamentals, Systems and Simulator Phases
  • Complete Simulator Certification
  • Perform other job‑related assignments and/or duties as assigned
Minimum Requirements Minimum education required of the position
  • B.S. Degree in Engineering or Sciences generally associated with nuclear power plant operations is highly desired, but not required if minimum experience requirements are met (NUREG 1021 and ACAD 00-003).
Minimum Experience Required Of The Position
  • Held an ACTIVE RO or SRO license at a Pressurized Water Reactor (PWR) commercial nuclear power plant (same vendor and vintage) for at least 12 months OR
  • Held an active Reactor Operator or Senior Reactor Operator license at a non-comparable commercial nuclear power plant for 18 months OR
  • 18 months as a manager, supervisor, or staff member responsible for the coordination and implementation of plant equipment controls, integrated operations procedure, operations, maintenance, radiological support, modifications maintenance planning, work control, chemistry, or accredited training at a current or comparable (BWR/PWR) nuclear power plant OR
  • At least 18 months as a qualified non‑licensed operator; OR
  • 24 months in a position equivalent to a reactor operator position at a military power reactor (qualified to manipulate or direct the manipulation of control rods) OR
  • 48 months as a senior operator level certified instructor at a PWR commercial nuclear power plant (same vendor and vintage) OR
  • 72 months as a senior operator level certified instructor at a non‑comparable facility.
  • Note: Bullet items 3 and 4 require a B.S. Degree in addition to the requirements listed.
Minimum Knowledge,

Skills And Abilities

Required Of The Position
  • Proficiency with current computer business applications. Outstanding communication and conflict management skills. Technical understanding of nuclear generation principles and operation.
Any Certificates, Licenses, Etc. Required For The Position
  • Minimum Requirements for Control Room Supervisor are defined in NUREG 1021 and INPO ACAD 00-003, Rev. 1 Guidelines for Initial Training and Qualification of Operators. Candidates must be currently Senior Reactor Operator licensed or meet these requirements for initial license. Technical understanding of…
To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)

Job Posting Language
Employment Category
Education (minimum level)
Filters
Education Level
Experience Level (years)
Posted in last:
Salary