×
Register Here to Apply for Jobs or Post Jobs. X

Fiber Optic Splicer

Job in New Albany, Franklin County, Ohio, 43054, USA
Listing for: Service Global, Inc.
Full Time position
Listed on 2026-08-08
Job specializations:
  • Trades / Skilled Labor
    Field/Service Technician, Telecoms Engineering, Installation Technician
Salary/Wage Range or Industry Benchmark: 70000 - 90000 USD Yearly USD 70000.00 90000.00 YEAR
Job Description & How to Apply Below

We are seeking experienced Senior Fiber Optic Splicers to support fiber break/fix, remediation, testing and restoration activities within an active hyperscale data center environment.

This is a production-level position for technicians who can independently diagnose and resolve fiber defects in both live/in-service and non-live fiber environments. The technician will be expected to own assigned defects from initial ticket review through repair, testing, documentation and closure.

Candidates must have recent, hands-on experience with single-fiber fusion splicing, ribbon/mass fusion splicing, SC connectivity, MTP/MPO systems and MMC high-density fiber connectivity. This is not a learn-on-the-job position, and routine technical issues should be resolved without requiring escalation back to the client.

Key Responsibilities:

Perform single-mode, single-fiber fusion splicing using repeatable fiber preparation, cleaving and splicing procedures.

Perform 12-fiber ribbon and mass fusion splicing, including ribboning fibers from loose-tube cable.

Work with SC, MTP/MPO and MMC fiber connectivity in high-density data center environments.

Install and repair splice-on connectors, pigtails, fan-outs and related fiber assemblies.

Diagnose and repair defects identified through audits, inspections, testing or trouble tickets.

Interpret fiber drawings, cable schedules, port assignments, splice plans and methods of procedure.

Understand MTP/MPO polarity methods, including Methods A, B and

C.

Verify MTP/MPO key orientation, pinned versus non-pinned configurations, gender and trunk/harness/cassette architecture.

Perform OTDR testing and interpret traces to identify events, excessive loss, reflections, breaks and fault locations.

Conduct insertion-loss testing using optical light sources and power meters.

Verify results against applicable loss budgets and project acceptance requirements.

Inspect and clean SC, MPO and other fiber end faces using appropriate inspection probes and cleaning tools.

Apply end face pass/fail standards consistent with project requirements and IEC 61300-3-35.

Follow live-environment safety procedures and never inspect an energized fiber directly.

Work strictly according to the approved ticket and method of procedure.

Avoid disconnecting, moving or disturbing fiber components that are not included in the assigned scope.

Document repairs, test results, photographs and supporting evidence before closing tickets.

Provide required morning, progress and end-of-day status updates.

Maintain splicing machines, cleavers, testing equipment and inspection tools in proper working condition.

Follow site safety requirements, including ladder, fall-protection, access-control and tool-control procedures.

Required Qualifications:

Demonstrated professional experience performing fiber fusion splicing in data center, colocation, enterprise or mission-critical environments.

Recent hands-on experience working with live/in-service fiber infrastructure.

Single-fiber fusion splicing

Ribbon or mass fusion splicing

Ribboning loose-tube fiber

SC terminations and patching

MTP/MPO connectivity

MMC high-density connectivity

Ability to independently diagnose, repair, test and close fiber defects.

Hands-on experience operating core-alignment fusion splicers such as:

Comparable professional fusion-splicing equipment

Proficiency with OTDRs, optical power meters, light sources and fiber inspection microscopes.

Ability to interpret OTDR traces rather than only operate the test equipment.

Understanding of insertion loss, loss budgets, splice-loss thresholds, reflectance and fiber cleanliness.

Ability to read fiber drawings, port maps, cable schedules and technical procedures.

Strong documentation and ticket-closure discipline.

Ability to work independently without routine client escalation.

Comfortable working in a safety-controlled, construction-oriented data center environment.

Experience Guideline:

Three or more years of directly relevant fiber-splicing experience is preferred. However, demonstrated capability with live data-center fiber, ribbon splicing, MPO/MMC and OTDR interpretation should carry more weight than total years of experience.

Preferred Qualifications

FOA Certified Fiber Optic Specialist in Splicing — CFOS/S

BICSI Installer or Technician certification

OSHA 10 or OSHA 30

Previous experience on Turner-managed construction sites

Experience supporting fiber audits, remediation, or live-network restoration

Ownership of professional hand tools, fiber preparation tools, or inspection equipment /p>#J-18808-Ljbffr

To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
 
 
 
Search for further Jobs Here:
(Try combinations for better Results! Or enter less keywords for broader Results)
Location
Increase/decrease your Search Radius (miles)
0
200
Filters
Education Level
Experience Level (years)
Posted in last:
Salary