More jobs:
IUOE Plant Operator, 1st Class
Job in
City of Rochester, Rochester, Monroe County, New York, 14602, USA
Listed on 2026-02-03
Listing for:
University of Rochester
Full Time
position Listed on 2026-02-03
Job specializations:
-
Engineering
Electrical Engineering, Mechanical Engineer
Job Description & How to Apply Below
IUOE Plant Operator, 1st Class page is loaded## IUOE Plant Operator, 1st Class locations:
Central Utilities time type:
Full time posted on:
Posted Todayjob requisition :
R267676
As a community, the University of Rochester is defined by a deep commitment to Meliora - Ever Better. Embedded in that ideal are the values we share: equity, leadership, integrity, openness, respect, and accountability. Together, we will set the highest standards for how we treat each other to ensure our community is welcoming to all and is a place where all can thrive.
** Job Location (Full Address):
** 390 Elmwood Ave, Rochester, New York, United States of America, 14620
** Opening:
** Worker Subtype:
Regular Time Type:
Full time Scheduled Weekly
Hours:
40
Department:100450 Sustainability & Energy Svcs
Work Shift:
UR - Day (United States of America)
Range:
UR IUOE 037 HCompensation Range:$33.21 - $43.11
* The referenced pay range represents the first and last step pay rates for this job, as set forth in the applicable collective bargaining agreement. Individual pay will be set in accordance with terms of the applicable collective bargaining agreement.
*** Responsibilities:
** Requires all around knowledge, experience and skill over and above that set forth in the job description for the basic job, or jobs, involved. Performs duties as set forth in the basic job description in addition to acting in the capacity of "instructor", "trouble shooter", "specialist", or similar categories. Usually is responsible to the Department Supervisor for the quantity and quality of the work of others in the group.
An element of leadership is necessary for effective guidance of others, but not to the extent usually associated with the jobs of SUPERVISORY level. Hiring, disciplining, promoting and firing are not contemplated within the scope of this classification. He or she may participate and assist in performance ratings of other employees in the group.
POSITION SUMMARY:
With considerable latitude for independent judgment and action, is responsible for instruction and direction of the Stationary Boiler Firemen on a shift and for efficient operation and safety of all related equipment to insure adequate steam supply required to meet the demands of the River Campus and Medical Center complex; and for the operation and safety of the chilled water plant and pumping station to satisfy requirements of the connected areas.
RECEIVED:
Boiler Room Foreman.
SUPERVISION AND DIRECTION EXERCISED:
Firemen. MACHINES AND EQUIPMENT USED:
I
- High Pressure Boilers and Related Equipment.e.g. 150,000 P.P.H.
B. and W. with spreader stoker and mechanically driven chain grates; 60,000 P.P.H. Combustion Engineering Boiler with manually op. grates.
100,000 P.P.H.
B.and W. with jet ignition stoker, and automatic mechanically driven chain grates. Bailey Automatic Boiler controls. Boiler feed water pumps (1 Electric and 3 Turbine Driven).Heavy duty fans. (Forced draft, induced draft, and over-fire air fans.)Electric hydraulic pumps used as motive power for stokers, grates etc.
Electric driven centrifugal pumps for heater water supply.
Condensate and vacuum pumps.
Auxiliary steam turbines. Air compressors as applied to pneumatic controls. Electrically operated lorry (1200 to 1500 lbs. capacity).Reducing valves for controlling steam flow to feed water heater to the Steam Distribution Systems. Hydraulic stoker drive coal handling equipment. Outside air supply dampers. Fluid couplings and oil coolers on induced draft fans.
Emergency generators and related switch gear. II
- Chilled Water Plant Equipment.e.g. 1500 ton carrier centrifugal refrigeration machine with 1400 H.P. turbine drive. 4500 ton carrier centrifugal refrigeration machine with 4800 H.P. Terry Turbine drive. Chilled water circulating pump (37 1/2 to 100 H.P.
-3000 to 6750 gallons per minute capacity). Refrigerant Receiver, Transfer pump. Auxiliary equipment such as: condensate pumps, condensate and cooling water pumps; air ejector condensers, pneumatic unit controls. Terry Turbine Driven
- Chilled Water Circulating Pump (342 H.P.
-13,500 G.P.M.)III
- Pumping Station Equipment:e.g. Air compressor for pneumatically operated condensing water…
To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
Search for further Jobs Here:
×