Electrical Design Analyst
Listed on 2026-08-04
-
Construction
Civil Engineering
Titusville, United States | Posted on 07/31/2026
RANDALL is a premier self-performing $100M+subcontractor providing integrated Mechanical, Electrical, Plumbing, Fire Protection, Architectural Metals, and Offsite Construction/Manufacturing solutions across Florida and the Southeast. With 35+ years of operational excellence and a team of 500+ professionals, we combine the grit and dedication of our grassroots origins with the innovation of a modern industry leader. Our
100,000 sq. ft. fabrication facility in Apopka, FL serves as a strategic logistics hub, supporting major commercial, industrial, and aeronautical projects across the Southeast and beyond.
RANDALL’sTitusville Electrical Division is seekinga top-tier, career-driven Electrical Design Analyst to support the successful estimating, planning, and delivery oflarge-scale commercial electrical construction projects along the Space Coast of Florida from our office in Titusville.
Position SummaryThe Design Analysis Specialist is responsible for reviewing construction drawings,specifications, design narratives, scopes of work, subcontractor proposals, and quantity takeoffs to identify design conflicts, missing information, quantity discrepancies, constructability concerns, and potential financial exposure before and during construction.
This position serves as the technical link between estimating, project management,field operations, BIM/VDC, engineering, general contractors, design professionals, vendors, and subcontractors. The primary objective is to verify that the written scope, design documents, quantities, labor assumptions,material requirements, and installation methods align before Randall Electrical commits to pricing or construction.
The roleis intended to reduce scope gaps, prevent unplanned costs, improve change-order documentation, and provide management with clear technical and financial analysis.
Essential Functions Drawing and Specification Review- Review electrical, civil,structural, architectural, mechanical, plumbing, fire-protection, and site drawings affecting Randall’s scope.
- Compare drawings against specifications, addenda, narratives, bid forms, schedules, and subcontractor proposals.
- Identify conflicts between planviews, details, one-line diagrams, schedules, sections, and written requirements.
- Confirm that issued-for-construction documents contain sufficient information to priceand construct the work.
- Track revisions between drawing sets and identify resulting scope, quantity, labor, and cost impacts.
- Maintain a design-analysis log showing open questions, responsible parties, required responses, and potential cost exposure.
- Independently verify major quantities, including:
- Conduit and duct-bank footage.
- Trench footage, width, depth, and excavation volume.
- Concrete encasement and flowable-fill quantities.
- Conductor sand cable lengths.
- Equipment counts.
- Grounding quantities.
- Manholes,pull boxes, hand-holes, supports, racks, and accessories.
- Confirm that material quantities align with the described installation configuration.
- Identify mathematical inconsistencies, duplicated quantities, missing quantities, and unsupported allowances.
- Develop calculation sheets showing the basis for each conclusion.
- Evaluate whether the proposed installation can be constructed as shown.
- Review access, sequencing,equipment needs, excavation limits, crane and lift requirements, material handling, and trade coordination.
- Identify conflicts involving elevations, clearances, routing, foundations, underground utilities,structural steel, mechanical systems, and architectural features.
- Evaluate whether proposed production rates are reasonable based on site conditions and installation requirements.
- Recommend alternative installation methods, prefabrication opportunities, and value-engineering options.
- Coordinate with field leadership to validate labor and production assumptions.
- Review vendor and subcontractor proposals before award.
- Confirm that proposal quantities, exclusions, clarifications, and assumptions agree with Randall’s contract requirements.
- Identify gaps between Randall’sscope and subcontracted scope.
- Prepare…
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).