Skip to content
×

Data Center Operations Specialist – Uptime & Infra Expert

Listing for: Salute
Full Time position Listed on 2026-11-08
Job specializations:
Salary/Wage Range or Industry Benchmark: 60000 - 90000 USD Yearly USD 60000.00 90000.00 YEAR

Job Description & How to Apply Below

If you are unable to complete this application due to a disability, contact this employer to ask for an accommodation or an alternative application process.

Data Center Operator

Operations Management Full Time Dedicated Hoffman Estates, IL, Hoffman Estates, IL, US

30+ days ago Requisition

The Data Center Operator (DCO) is a facilities-focused role responsible for the operational integrity, commissioning, and regulatory compliance of the electrical power, mechanical, monitoring and control systems, and the processes that maximize customer uptime in the most cost-effective way for highly available, concurrently maintainable, fault tolerant mission-critical data center environments.

The DCO ensures that all electrical, mechanical, and fire/life safety equipment within the data center operates at peak efficiency and the utmost levels of reliability. This involves planned preventive maintenance, daily corrective work, and response to emergency issues. The DCO is our front line for hands-on electrical and mechanical troubleshooting and serves as an expert technical resource reporting to the Site Manager, interacting with On-Site Multi-Skilled Operators (MSOs) and third-party vendors.

In this role the DCO is also the technical authority over vendor work on site. In addition to scheduling and escorting vendors; the DCO reviews and approves their procedures, witnesses critical steps, verifies results against OEM and industry criteria, and decides when work may start, stop, or be closed out. The DCO is the singular focal point for all facility operations within a given data center.

Equipment that supports mission-critical servers must maintain better than 99.999% uptime. This equipment includes, but is not limited to, standby diesel generators and related fuel systems, electrical switch gear, UPSs, PDUs, AHUs, thermal management equipment and systems, coolant distribution units (CDUs) and facility water loops for liquid cooling, chemical treatment systems (where applicable), pumps, motors, VFDs, and building automation systems.

Responsibilities

Safety and core operations

  • Place SAFETY at the top of anything and everything done, without fail, and remain consistently focused on SAFETY in every task.
  • Operate, monitor, maintain, and respond to abnormal conditions of facility systems.
  • Conduct periodic inspections of building systems (HVAC, electrical distribution) and keep mechanical equipment rooms and enclosures clean, functional, and safe.
  • Rapid response, investigation, and management of indoor emergency situations and air quality complaints, including humidity.
  • Maintain complete working knowledge of creating, closing, and tracking work requests (WR); initiate or respond to work orders, follow up, and verify completion of work.

Preventive maintenance and corrective repairs

  • Complete planned and ad-hoc preventive maintenance assignments requiring the skill and direction of several electrical, mechanical, and maintenance trades and engineering disciplines.
  • Witness critical steps of vendor preventive maintenance and check the work performed against the OEM maintenance checklist before accepting it.
  • Diagnose corrective issues, set the repair scope with the vendor, and approve the proposed fix before the work order is closed out.
  • Work with the Site Manager and other stakeholders to track and complete a preventive and predictive maintenance schedule for critical maintenance and system commissioning.

Vendor procedures, pre-job briefs, and stop work authority

  • Review each vendor Method of Procedure (MOP) before work begins and reject it if it is incomplete, unsafe, or does not meet OEM and site requirements.
  • Lead the pre-job brief for vendor work, covering scope, sequence, hazards, rollback, and acceptance criteria.
  • Exercise stop-work authority for quality and acceptance concerns as well as safety, and delay or hold work that does not meet requirements.
  • Lead switching operations, or directly supervise the vendor performing switching, in line with the approved MOP and NFPA 70E practices.

Test results, return to normal, and warranty

  • Read the as-found and as-left test data supplied by vendors and reject out-of-range results against NETA, IEEE, and OEM acceptance criteria.
  • Confirm redundancy is restored and alarms are back to normal before signing off a work order, in addition to restoring the area to its original condition.
  • Track equipment trends and reliability reports, flag repeat failures, and pursue warranty claims with vendors and OEMs.

Vendor performance and…

To View & Apply for jobs on this site that accept applications from your location or country, tap the button below to make a Search.
(If this job is in fact in your jurisdiction, then you may be using a Proxy or VPN to access this site, and to progress further, you should change your connectivity to another mobile device or PC).
View / Apply for Jobs
Matching My Jurisdiction

Search for further Jobs Here:

SEARCH JOBS: 10+ Million Listings
(Try combinations for better Results! Or enter less keywords for broader Results)
Education Level
Experience Level (years)
Posted in last:
Salary